MASTR II UHF Exciter Re-Alignment The exciter metering jack is located just below T108. As with the receiver, use an analog meter (VTVM). All measurements are from the metering jack ground pin 8 or 9 to the pin called out in the alignment steps. Measure
on pin 1 and tune T103 for maximum meter reading. Measure on pin 3 and tune T104 for a dip. Measure on pin 4 and tune T105 for maximum, re-adjust T104 for maximum and tune T106 for a dip. Measure on pin 7 and tune T107 for maximum, re-adjust T106 for maximum then tune T108 for a dip and T109 for maximum. Measure from pin 5 and tune T110 for maximum and re-adjust T108 and T109 for maximum. Measure from pin 4 of the PA metering jack and tune T111 and T112 for maximum meter reading. Measure from pin 5 of the exciter's metering jack and re-adjust T108, T109, and T110 for maximum meter reading. Measure form the PA's meter jack, pin 4 and re-adjust T111 and T112 for maximum meter reading. The exciter puts out about 250 mw of RF power, adjust the
ICOM frequency to the frequency of interest using a frequency counter properly
connected to the exciters output. Remember, this is the alignment process
for the silver handle UHF M2, so the exciter's frequency out put should be 1/3
of the transmit frequency. Also remember to factor in the
temperature curve chart when adjusting the transmitter ICOM.
|